spanduk
Beranda

Ruang Uji Suhu Walk-In

Ruang Uji Suhu Walk-In

  • Energy-Saving Environmental Test Chamber: Safeguard Your Long-Term Product Costs
    Dec 01, 2025
    For enterprises in manufacturing, electronic technology, and related industries, product reliability testing is a critical quality assurance link. However, the operational costs of environmental test chambers—core testing equipment—are often overlooked. Many businesses focus solely on testing precision during procurement, only to be troubled by high energy bills in long-term use. Our energy-saving environmental test chamber effectively resolves the conflict between "accurate testing" and "cost control," providing comprehensive support for product lifecycle cost management. Core Energy-Saving Feature: Intelligent Refrigeration System Regulation As the primary energy-consuming component of environmental test chambers, the energy regulation technology of the refrigeration system directly determines the equipment’s energy efficiency. On the premise of meeting core technical indicators, this test chamber innovatively integrates multiple energy adjustment measures to achieve intelligent dynamic control of refrigeration capacity. The system precisely regulates evaporation temperature via the controller and links it with a hot gas bypass energy adjustment mechanism, matching refrigeration demand in real time based on the required cooling rate and target temperature range. When approaching the set low temperature, the system automatically reduces refrigeration capacity to avoid temperature overshoot—a common issue in traditional models—ensuring test stability. During the constant temperature phase, it abandons the energy-intensive "hot-cold balance" mode, optimizing energy utilization at the source. Verified in real operating conditions, the energy-saving effect reaches up to 30%, significantly reducing long-term operational costs, especially for enterprises requiring 24/7 continuous operation. Precision & Energy Efficiency: Optimized Heating System Power Control Refined control of the heating system further enhances the equipment’s energy-saving advantages and temperature control precision. The system adopts a synergistic control scheme of temperature controllers and thyristors: the temperature controller collects real-time temperature signals and issues control commands, while thyristors precisely adjust the heater’s power output. When the temperature is far below the set value, thyristors deliver full power for rapid heating. As the temperature gradually approaches the set value, the output power decreases incrementally; once the target temperature is reached, power output stops immediately. This on-demand power distribution mode eliminates energy waste and ensures precise temperature control, providing a stable and reliable temperature environment for tests. For example: When the internal temperature is significantly lower than the set value, thyristors operate at full power, and the heater runs at maximum load to ensure rapid temperature rise. As the temperature nears the target, the thyristor’s output power gradually decreases. Once the target temperature is achieved, the thyristor stops power output immediately, and the heater enters standby mode. This "on-demand power supply" mode eliminates the drawback of "frequent start-stop" in traditional heating systems—avoiding ineffective energy consumption while greatly improving temperature control precision, making it particularly suitable for test scenarios requiring high temperature stability. Dual-System Synergy: Safeguard Enterprise Costs From the refrigeration system’s intelligent energy adjustment to the heating system’s precision power control, our environmental test chamber centers on dual-system collaborative energy-saving technology. While ensuring accurate test data, it maximizes energy cost reduction. Choosing our test chamber not only guarantees product testing quality but also enables scientific management of enterprise operational costs, providing peace of mind throughout your product R&D and production processes. In addition, if your enterprise is seeking a cost-effective environmental test chamber or struggling with high energy consumption from existing equipment, we recommend focusing on our energy-saving model. Let professional equipment protect your product quality while reducing costs and enhancing efficiency for your business.
    BACA SELENGKAPNYA
  • Got Your Temperature Test Chamber? Here’s What You Must Do Next!
    Nov 28, 2025
    I. Receipt Inspection  1. Physical Verification Confirm equipment model, specifications, and serial number match the contract/packing list to avoid wrong delivery. Inspect the cabinet, door, and control panel for transportation damage (dents, deformation) and ensure pipelines/wiring are intact without loosening. 2. Accessory & Document Check Required accessories: Power cord, sample shelves, sealing rings, wrenches, and other tools (verify against the packing list). Technical documents: Operation/maintenance manual, calibration certificate, warranty card, and qualification certificate (all mandatory for after-sales service). 3. Abnormal Handling In case of damage or missing items: Immediately take photos (overall equipment, damaged details, packing list), notify the supplier within 24 hours to submit a claim, and sign the "Acceptance Objection Form" for documentation. II. Installation & Deployment (Compliant Installation Ensures Performance) 1. Environment Requirements (Must Meet the Following) Floor: Flat and sturdy, with load-bearing capacity ≥1.2 times the equipment weight (to avoid test errors caused by vibration). Space: ≥30cm ventilation gap around the cabinet; keep away from heat sources, water sources, dust, and strong electromagnetic interference. Power supply: Match the rated voltage (e.g., 380V three-phase five-wire/220V single-phase), grounding resistance ≤4Ω, and equip an independent air switch (power ≥1.2 times the equipment's rated power). Environment: Room temperature 15-35℃, humidity ≤85%RH (no condensation); water-cooled models require pre-connected cooling water circuits meeting specifications. 2. Basic Installation Steps Level the equipment: Adjust anchor bolts and use a level to confirm horizontal alignment (to prevent uneven stress on the refrigeration system). Wiring inspection: Connect the power supply per the manual and ensure correct neutral/grounding connections (a common cause of electrical failures). Consumable check: Confirm refrigerant and lubricating oil (if applicable) are properly filled with no leakage. III. Commissioning (Core: Verify Performance Compliance) 1. First Startup Procedure (1) Recheck power/pipeline connections before power-on; switch on after confirmation. (2)Panel self-test: Ensure the display shows no error codes and buttons/indicators function normally. (3)No-load operation (2-4 hours): Set a common temperature range (e.g., -40℃~85℃) and monitor temperature fluctuation ≤±0.5℃ (meets industrial standards). Check door sealing (no obvious air leakage), operating noise ≤75dB, and normal start/stop of refrigeration/heating systems. 2. Load Verification (Simulate Actual Usage) Place a load equivalent to the test sample (weight/volume ≤80% of the equipment's rated load) without blocking air ducts. Set the target temperature and holding time; record if the heating/cooling rate meets technical parameters (e.g., -40℃~85℃ heating time ≤60 minutes). Alarm test: Simulate power failure, over-temperature, or door-open timeout to confirm timely alarm response (audio-visual alarm + shutdown protection). IV. Emergency Handling & After-Sales Coordination 1. Common Fault Resolution Error codes: Refer to the "Troubleshooting" section in the manual (e.g., E1=Over-temperature, E2=Power abnormality). Sudden failures: (e.g., electric leakage, abnormal noise, refrigeration failure) Immediately cut off power, stop use, and contact the supplier's technical support (do not disassemble independently). 2. After-Sales Support Retain the supplier's after-sales contact (phone + email) and confirm the warranty period (usually 1 year for the whole machine). Maintenance records: Request a "Maintenance Report" after each service and file it for future tracing.
    BACA SELENGKAPNYA
  • Pengenalan Ruang Uji Suhu Walk-in
    Feb 24, 2025
    Ruang Uji Suhu Walk-In adalah laboratorium besar yang memperbolehkan operator untuk masuk ke dalamnya, terutama digunakan untuk pengujian lingkungan. Umumnya digunakan untuk menguji komponen besar, produk setengah jadi, dan produk jadi untuk mensimulasikan suhu lingkungan dunia nyata, dan banyak digunakan dalam industri seperti teknik listrik, peralatan listrik, instrumen, elektronik, keamanan, komunikasi, sensor, otomasi, kontrol industri, mesin presisi, dll. Ruang Uji Suhu Walk-in dilengkapi dengan lubang uji φ 50mm dengan colokan di sisi kotak. Bahan colokan adalah karet silikon berbusa rendah, yang dapat menahan suhu tinggi dan rendah dan memiliki efek isolasi. Pemanas mengadopsi pemanas listrik kawat nikel kromium rangka porselen, yang memiliki inersia termal rendah dan masa pakai yang lama. Instrumen mengeluarkan sinyal PID siklus kerja pulsa yang dapat dikontrol, yang dikontrol oleh relai solid-state untuk membuat kontrol lebih lancar dan lebih andal. Kinerja dan karakteristik Kamar Uji Suhu Walk-in: 1. Memiliki rentang kendali suhu dan kelembapan yang sangat luas, yang dapat memenuhi berbagai kebutuhan pengguna. Dengan mengadopsi metode kendali suhu dan kelembapan seimbang yang unik, lingkungan suhu dan kelembapan yang aman dan tepat dapat dicapai. Memiliki kinerja pemanasan dan pelembapan yang stabil dan seimbang, dapat mencapai kendali suhu dan kelembapan presisi tinggi. 2. Dilengkapi dengan pengatur suhu cerdas, suhu dan kelembapan ditampilkan menggunakan layar digital LED. Ruang uji panas lembap suhu tinggi dan rendah dapat secara opsional dilengkapi dengan perekam suhu dan kelembapan. 3. Pemilihan otomatis sirkuit pendingin, perangkat kontrol otomatis memiliki kinerja pemilihan dan pengoperasian otomatis ke sirkuit pendingin sesuai dengan nilai suhu yang ditetapkan, mewujudkan permulaan langsung mesin pendingin dan pendinginan langsung dalam kondisi suhu tinggi. 4. Pintu bagian dalam dilengkapi dengan jendela observasi besar, yang memudahkan pengamatan status eksperimen sampel uji. 5. Dilengkapi dengan perangkat keselamatan dan perlindungan canggih - pemutus arus sisa, pelindung suhu berlebih, pelindung kehilangan fase, dan pelindung pemutus air. Kami dapat menyediakan ruang uji suhu tinggi dan rendah, ruang uji suhu rendah, ruang uji suhu dan kelembapan konstan, ruang uji panas lembap suhu tinggi dan rendah, ruang uji panas lembap bergantian suhu tinggi dan rendah, ruang uji korosi semprotan garam. Ruang uji di atas dapat disesuaikan menurut kebutuhan Anda. Oleh karena itu, Walk-in Temperature Test Chamber cocok untuk perusahaan dengan tuntutan tinggi terhadap pengujian lingkungan dan ruang operasional.
    BACA SELENGKAPNYA

Tinggalkan pesan

Tinggalkan pesan
Jika Anda tertarik dengan produk kami dan ingin mengetahui lebih detail, silakan tinggalkan pesan di sini, kami akan membalas Anda sesegera mungkin.
kirim

Beranda

Produk

Ada apa

Hubungi kami